Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13600428

- Product Categories
- Friendly Links
- home > Supply > Blood pressure measurement system, tail arterial blood pressure analysis system, noninvasive blood pressure analysis system
Blood pressure measurement system, tail arterial blood pressure analysis system, noninvasive blood pressure analysis system
Information Name: | Blood pressure measurement system, tail arterial blood pressure analysis system, noninvasive blood pressure analysis system |
Published: | 2014-12-27 |
Validity: | 100 |
Specifications: | Standard |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | ZH-HX-Z noninvasive blood pressure measurement and analysis system tail digital, intelligent, sensitive automated noninvasive blood pressure measurement system, has been a long-term non-invasive blood pressure measurement practice, has been well received. Blood pressure measurement is used, the animals without anesthesia, non-invasive, accurate measurement, convenient and practical. System accurately records show systolic blood pressure, diastolic blood pressure, mean pressure and heart rate, automatic processing of data, results and statistics are automatically stored period of time, especially for applications that require long-term repeated measurement of blood pressure. Enable non-invasive blood pressure measurement work more scientific, more accurate, and easier. A measuring device structure: 1, inflatable ball: blood pressure cuff sets the table and communicated to regulate pressure cuff sleeve. 2, blood pressure meter: Show pressure cuff sleeve and the entire pipeline system. 3, cuff sleeve: inside the hard shell capsule and latex composition, internal capsule pressure control by artificial inflatable ball, oppression or release arteries. 4, high-sensitivity pulse transducers: a key part, it can feel tiny critters arterial pulse and pulse into an electrical signal, via micro-electric amplifier systems, pulse tracings moving out the curve. For time to identify systolic and diastolic arise. 5, the transducer interface: for connecting a pressure transducer via a pressure transducer to record the pressure curve pressure within the pipe. Second, the principle: The measuring instrument works with Klinefelter sound principles of ordinary human blood pressure measurement of arterial blood pressure similar body. High-sensitivity transducers can feel the pulse of the arterial blood flow changes resulting from the strength of the different vascular pulsation, the transducer and the enlargement process, through a variety of display systems tracings recorded a vascular pulsation curve. By way of artificially inflated jacket cuff pressure change, the implementation of oppression artery (blocked blood flow) and release (restoration of blood flow). When the pressure in the artery tail kit from completely blocked artery to the heart to make the start through the ejection, when the pulse wave to emerge from the first wave disappeared again, on this wave occurs when the corresponding gauge artery systolic pressure indication representatives. Then sleeve cuff pressure is gradually decreased, the pulse wave gradually increased, when the tail kit just in diastolic pressure of arterial blood flow does not hinder, this time no longer increases the pulse wave curve and produce a secondary peak, the peak Representative diastolic blood pressure corresponding to the pressure. Time systolic and diastolic blood pressure occurs by high-sensitivity pulse transducer pulse curve transducer was provided signs. Pulse wave to appear completely disappeared from the first pulse wave, in this wave corresponding to systolic pressure pipeline. Jacket cuff pressures continue to gradually reduce, and gradually increase the pulse wave and generate baseline shift, the emergence of a two peak, the highest point of the peak (or pulse wave increases to a point of no increase) corresponding diastolic blood pressure. ALC-NIBP noninvasive blood pressure measurement and analysis system, digital, intelligent, automated noninvasive blood pressure measurement system sensitivity. 2, optional 1 to 16 channels simultaneously measure multiple animal blood pressure. 3, charge and discharge gas control all automated, more standardized, more scientific, to improve the measurement accuracy. 4, the automatic determination of systolic blood pressure, diastolic blood pressure, mean pressure and heart rate. 5, automatic measurement cycle experiment, just click, determined automatically by the system to complete. 6, in the course of each measurement, automatic determination of the average number of times, the result is more accurate. 7, automatically saves the accumulated data for each animal and each experiment, eliminating the need to manually record data. 8, the cumulative results database can easily export and import, easy to use. 9, automatic processing, storage and statistical results given period. 10, data can be imported directly into Excel's statistical tables, statistical analysis and charting. 11, record keeping as bmp graphic file, you can handle any graphics editing software, easy to use. 12, the original data is saved, you can always repeat and re-measured. 13, elaborate equipment, the accumulation of long-term non-invasive blood pressure measurement experience, unique design, thoughtful, to ensure non-invasive blood pressure measurement. 14, specially designed thermostat experimental box, measuring temperature can be set to provide blood pressure was measured at a constant temperature conditions, warranties measurement environment, fast and convenient. 15, specially designed rear heater, only the tail of the heating thermostat heater, easy to use, the tail heating will reduce the overall impact of the animals to a minimum. Digital, intelligent, sensitive automated noninvasive blood pressure measurement system, has been a long-term non-invasive blood pressure measurement practice, has been well received. For rats, mice, dogs (dogs), cats, rabbits, monkeys and other animals, blood pressure measurements, the animals without anesthesia, non-invasive, accurate measurement, convenient and practical. System accurately records show systolic blood pressure, diastolic blood pressure, mean pressure and heart rate, automatic processing of data, results and statistics are automatically stored period of time, especially for applications that require long-term repeated measurement of blood pressure. Enable non-invasive blood pressure measurement work more scientific, more accurate, and easier. Digital, intelligent, sensitive automated noninvasive blood pressure measurement system, optional 1 to 16 channels simultaneously measure multiple animal blood pressure and improve efficiency. Plot long-term non-invasive blood pressure measurement experience and unique fixtures designed scientific design, easy measurement. Charge and discharge gas controls all automated, more standardized, more scientific, to improve the measurement accuracy. Specially designed rear heater, only the tail of the heating thermostat heater, very easy to use. Overall impact on animals is reduced to a minimum. Specially designed test chamber thermostat, measuring temperature can be set to provide blood pressure was measured at a constant temperature conditions, warranties measurement environment, fast and convenient. |
Admin>>>
You are the 14450 visitor
Copyright © GuangDong ICP No. 10089450, Anhui is China Biological Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 14450 visitor
Copyright © GuangDong ICP No. 10089450, Anhui is China Biological Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility